AIRWALL CALL MED

Info Request
Description:

AIRWALL CALL MED is a lighting applique complete with a command call system for nurse call and one UNEL socket on lateral end cap.
The suggested teach has between one and three commands allowing the patient to call for nurse and service assistance (one command), together with the independent starting or turning off of the general and reading light (two and three commands). 
It is possible to valuate eventual a tailormade solutions and to arrange the AIRWALL CALL MED with other teach, different from the one we suggest but compatible with the most common call systems.
AIRWALL CALL MED is a medical device coming from I class according with the 93/42/CE directive and smi (2007/47/CE directive). According with the CEI EN 60601-1:2007+A11/2012 and UNI EN ISO 11197:2009 regulation, it is also an electromedical device from the I isolation class.


General information
  • Body: Steel structure, lateral aluminium end caps, extruded aluminium frontal profile
  • Diffuser: Glazed opal polycarbonate diffuser for indirect lighting - Opal polycarbonate diffuser for direct lighting.
  • Protection degree IP: IP20 general - IP40 lighting circuit - IP21 electrical sockets
  • Standard colour: Dry White
  • SURFACE TREATMENT ON REQUEST: Antimicrobial coating
  • Standard equipment: - 2 COMMANDS CALL SYSTEM (complete with an electronic command in a lighting control relay): request of assistance from the medical and service staff and light starting. - UNEL socket 2P+T 10/16A
LIGHTING FEATURES
For version 1270 mm long
  • Indirect light: 36W - 3248lm - 4000K - CRI>90
  • Direct light: 20W - 896lm - 4000K - CRI>90
  • Night light: 3W - 155lm - 4000K - CRI>90
DIMENSIONS:
A: 285 mm
B: 880 mm - 1180 mm - 1380 mm
C: 120 mm
D: 90 mm
CLASSIFICATION ACCORDING TO THE 93/42/CEE DIRECTIVE
I class (no gas) - IIa/IIb (with gas)
- Non-stop operation
- No sections are applie
- Suitable for the installation in group 0, 1 and 2 medical premises
- Not suitable for the installation in explosion risk environments (locations with gases and flammable vapours)
- Not suitable for the installation in environments with an oxygen amount superior to the 25% with an environmental pressure until the 110kPa in usual circumstances
- Not suitable for the categories AP and APG provisions

REFERENCE DIRECTIVES AND REGULATIONS
93/42/CEE; UNI EN ISO 11197; CEI EN 60601-1; CEI EN 60598; CEI EN 55015; CEI EN 61547; UNI CEI EN ISO 14971; UNI CEI EN ISO 13485
TELL YOUR NEEDS


We are specialists in designing customized lighting solutions in a short time.
If you are an architect, a designer or a manager, contact us to explain your needs in detail.